Back to Top

1
Hi, Guest!

Coulometric Titrator

Update Terakhir
:
21 / 08 / 2020
Min. Pembelian
:
1 Unit
Harga
CALL
Mengambil respon ini sebagai moto, PT. Berkat Jaya Abadi, didirikan di surabaya pada tahun 2001 dengan tujuan untuk berkontribusi pada proses modernisasi, khususnya dalam teknologi ilmiah di indonesia , dan berfungsi sebagai langkah awal untuk pembangunan Indonesia.

Detail Coulometric Titrator

Karl Fischer titration is simply a means to measure water content of samples. Modern instruments, such as the Aquamax KF, use the coulometric principle, whereby the water present in the sample is coulometrically titrated to a predefined end point at which there is a minute excess of free iodine present. Stoichiometrically, 1 mole of water will react with 1 mole of iodine, so that 1 milligram of water is equivalent to 10.71 coulombs of electricity. Combining the coulometric technique with Karl Fischer titration, Aquamax KF titrators determine the water content of the sample by measuring the amount of electrolysis current necessary to produce the required iodine. This is an absolute technique which does not require calibration of the reagents. Using the latest pulse current technology and our patented “ ACE” control system, ( Patent No.GB2370641) , the Aquamax KF automatically selects the appropriate titration speed dependent upon the amount of water present in the sample. The titration speed is reduced as the end point is approached, and when the titration is completed the instrument prints out and displays the results.
Tampilkan Lebih Banyak
cv. berkat jaya abadi
cv. berkat jaya abadi

CV. BERKAT JAYA ABADI

Anggota PREMIUM 11 Tahun
Jl.Wonorejo Permai Timur VI no. 6 (Nirwana Eksekutif Blok EE -111, Surabaya
Indonesia 60263
Surabaya
12 / 08 / 2021
Hubungi Kami

Detail Coulometric Titrator

Karl Fischer titration is simply a means to measure water content of samples. Modern instruments, such as the Aquamax KF, use the coulometric principle, whereby the water present in the sample is coulometrically titrated to a predefined end point at which there is a minute excess of free iodine present. Stoichiometrically, 1 mole of water will react with 1 mole of iodine, so that 1 milligram of water is equivalent to 10.71 coulombs of electricity. Combining the coulometric technique with Karl Fischer titration, Aquamax KF titrators determine the water content of the sample by measuring the amount of electrolysis current necessary to produce the required iodine. This is an absolute technique which does not require calibration of the reagents. Using the latest pulse current technology and our patented “ ACE” control system, ( Patent No.GB2370641) , the Aquamax KF automatically selects the appropriate titration speed dependent upon the amount of water present in the sample. The titration speed is reduced as the end point is approached, and when the titration is completed the instrument prints out and displays the results.
Tampilkan Lebih Banyak
Kontak Kami